Feature
|
Benefit |
3 operating modes:
Normal, bar hole, and leak check |
 |
3 instruments, 1 monitor. Reduce the number of instruments your service specialists must carry. |
Smallest 5 sensor sample draw
instrument |
 |
Convenient in tight spaces. Ideal for appliance leak checks. Comfortably fits on belts. |
Leak Check Mode
|
 |
Provides low ppm detection of combustible gases for leak investigations. |
| Leak Check Blink Rate |
 |
The blink rate of the LED’s and alarm tones increases in frequency as the concentration of the sample increases, making it easier to find the source of a leak. |
| Audible Alarm Silence |
 |
Service specialist can perform leak investigations without alarming residents with the
audible alarm in the off mode. The reading and bar graph are displayed as well as flashing LED’s. |
| Bar Hole Mode |
 |
Locates underground leaks quicker and more accurately by using fixed time sampling periods and storing the peak methane reading and minimum oxygen levels. The sample system shuts off and purges automatically at the end of each sample. |
| Auto ranging with combustible gas |
 |
Leak surveys are simplified with no set up or special modes to enter. Automatically ranges % LEL to % volume based on the sample. Displays appropriate unit of measure. Minimizes operator training and eliminates special range setup. |
Interchangeable Ni-MH or Alkaline
power |
 |
Avoid instrument down time with the flexibility of interchangeable alkaline or NiMH batteries.
Ni-MH fully recharges in 90 minutes. |
| Internal Sample Drawing Pump |
 |
Maintains a steady sample flow to the sensors and provides up to a 40’ range. |
| Low flow alarm |
 |
Immediate warning when the flow of the sampling system is obstructed. |
| Vibration, audible, and visual alarms |
 |
3 ways to communicate with the service specialist. |
| Calibration Reminder / Lock Out |
 |
Prevent instruments that are out of calibration from going into the field with the calibration
reminder or lock out. |
| Quick Start Up |
 |
Reduce man-hours of service specialists. No longer have to wait 3 to 4 minutes for each
instrument to start up. |
| Protective Rubber Boot |
 |
Protects the instrument in high impact situations. |
| Datalogging |
 |
Stores up to 600 hours of data for service and liability record keeping. |
| Data Cal 2000 |
 |
Automate the service and records for one or for an entire fleet of instruments. |
| Low cost of ownership |
 |
With the lowest sensor replacement cost, the cost of ownership is the best value of any instrument available. |